Actual values

9
Actual values
The various control functions and methods include electrical control variables and various calculated
actual values of the machine or system. The different actual values can be read out for operational
and error diagnosis via a communication interface or in the "Actual" menu of the operator panel.
9.1

Actual values of frequency inverter

No.
Description
222
DC–link voltage
223
Modulation
Internal Reference Fre-
228
quency
229
Reference percentage
230
Actual percentage value
243
Digital Inputs (Hardware)
244
Working hours counter
245
Operation hours counter
246
Capacitor temperature
249
Active data set
250
Digital inputs
251
Analog input MFI1A
Actual values of frequency inverter
Actual values of frequency inverter
Direct voltage in DC-link.
Output voltage of the frequency inverter relative to the mains
voltage (100% = U
Total of
Reference frequency source 1
492.
quency source 2
Total of
Reference percentage source 1
percentage source 2
percentage channel.
Actual value signal at the
Status of digital inputs in decimally encoded form:
− of enable signal (STOA AND STOB)
− of the six digital inputs
− of multifunction input 1 in setting
452 "3 - digital NPN (active: 0 V)" or "4 - digital PNP (ac-
tive: 24 V)".
− of multifunction input 2 in setting
562 "3 - digital NPN (active: 0 V)" or "4 - digital PNP (ac-
tive: 24 V)".
− of digital input/output in setting
558 = "0 - input IN3D".
X11.6
Represents the status of the physical inputs (also refer to actual
value
Digital inputs
Operating hours in which the output stage of the inverter is
active.
Operating hours of the frequency inverter in which supply volt-
age is available.
Measured capacitor temperature. Warning or shutdown if tem-
perature is too high.
According to
Data set change-Over 1
71 of the data set currently used.
Over 2
Status of digital inputs in decimally encoded form:
− of enable signal (STOA AND STOB)
− of the six digital inputs
− of multifunction input 1 in setting
452 "3 - digital NPN (active: 0 V)" or "4 - digital PNP (ac-
tive: 24 V)".
− of multifunction input 2 in setting
562 "3 - digital NPN (active: 0 V)" or "4 - digital PNP (ac-
tive: 24 V)".
− of digital input/output (terminal X11.6) in setting
mode terminal X11.6
Input signal at multifunction input 1. Via parameter
452, multifunction input 1 must be set up as a
mode MFI1
voltage or current input.
265
Function
).
FIN
475 and
476 and
494 as reference value of the reference
Actual percentage source
Operation mode MFI1
Operation mode MFI2
Operation mode terminal
250).
70 and
Operation mode MFI1
Operation mode MFI2
558 = "0 - input IN3D".
06/2013
Operating Instructions