Section 7: TSP command reference

tsplink.trigger[N].mode

This attribute defines the trigger operation and detection mode. This attribute is not available on the Models
2604B/2614B/2634B.
Type
TSP-Link accessible
Attribute (RW)
Yes
Usage
mode = tsplink.trigger[N].mode
tsplink.trigger[N].mode = mode
mode
N
Details
This attribute controls the mode in which the trigger event detector and the output trigger generator operate on
the given trigger line.
The setting for mode can be one of the following values:
Mode
tsplink.TRIG_BYPASS
tsplink.TRIG_FALLING
tsplink.TRIG_RISING
tsplink.TRIG_EITHER
tsplink.TRIG_SYNCHRONOUSA
tsplink.TRIG_SYNCHRONOUS
tsplink.TRIG_SYNCHRONOUSM
tsplink.TRIG_RISINGA
tsplink.TRIG_RISINGM
7-358
Series 2600B System SourceMeter® Instrument Reference Manual
Affected by
Instrument reset
Recall setup
TSP-Link trigger N reset
The trigger mode
The trigger line (1 to 3)
Number
Description
value
0
Allows direct control of the line as a digital I/O line.
1
Detects falling-edge triggers as input. Asserts a TTL-low pulse
for output.
2
If the programmed state of the line is high, the
tsplink.TRIG_RISING mode behaves similarly to
tsplink.TRIG_RISINGA.
If the programmed state of the line is low, the
tsplink.TRIG_RISING mode behaves similarly to
tsplink.TRIG_RISINGM.
Use tsplink.TRIG_RISINGA if the line is in the high output
state.
Use tsplink.TRIG_RISINGM if the line is in the low output
state.
3
Detects rising- or falling-edge triggers as input. Asserts a
TTL-low pulse for output.
4
Detects the falling-edge input triggers and automatically
latches and drives the trigger line low.
5
Detects the falling-edge input triggers and automatically
latches and drives the trigger line low. Asserts a TTL-low pulse
as an output trigger.
6
Detects rising-edge triggers as an input. Asserts a TTL-low
pulse for output.
7
Detects rising-edge triggers as input. Asserts a TTL-low pulse
for output.
Edge detection as an input is not available. Generates a
8
TTL-high pulse as an output trigger.
Where saved
Default value
Not saved
0 (tsplink.TRIG_BYPASS)