P
E
C
OWER OVER
THERNET
OMMANDS
-
DEBUG POWER
INLINE

debug power-inline

Overview
This command enables debugging display for messages that are specific to Power
over Ethernet (PoE).
Use the no variant of this command to disable the specified PoE debugging
messages.
Syntax
debug power-inline [all|event|info|power]
no debug power-inline [all|event|info|power]
Default
No debug messages are enabled by default.
Mode
Privileged Exec
Usage
Use the
console.
Use the
configuration.
Examples
To enable PoE debugging and start the display of PoE event and info debug
messages on the console, use the following commands:
awplus#
awplus#
To enable PoE debugging and start the display of all PoE debugging messages on
the console, use the following commands:
awplus#
awplus#
To stop the display of PoE info debug messages on the console, use the following
command:
awplus#
To disable all PoE debugging and stop the display of any PoE debugging messages
on the console, use the following command:
awplus#
C613-50103-01 REV A
Parameter
Description
all
Displays all (event, info, nsm, power) debug messages.
event
Displays event debug information, showing any error conditions
that may occur during PoE operation.
info
Displays informational level debug information, showing high-level
essential debugging, such as information about message types.
power
Displays power management debug information.
terminal monitor
show debugging power-inline
terminal monitor
debug power-inline event info
terminal monitor
debug power-inline all
no debug power-inline info
no debug power-inline all