Loop-Protection Loop-Detect - Allied Telesis x310-26FT Command Reference Manual

X310 series stackable access switches for alliedware plus version 5.4.6-1.x
Table of Contents

Advertisement

S
C
WITCHING
OMMANDS
-
-
LOOP
PROTECTION LOOP
DETECT

loop-protection loop-detect

Overview
Use this command to enable the loop-protection loop-detect feature and
configure its parameters.
Use the no variant of this command to disable the loop-protection loop-detect
feature.
Syntax
loop-protection loop-detect [ldf-interval <period>]
[ldf-rx-window <frames>] [fast-block]
no loop-protection loop-detect
Default
The loop-protection loop-detect feature is disabled by default. The default interval
is 10 seconds, and the default window size is 3 frames.
Mode
Global Configuration
Usage
See the "Loop Protection" section in the
Configuration Guide
information prior to applying this command.
Example
To enable the loop-detect mechanism on the switch, and generate loop-detect
frames once every 5 seconds, use the following commands:
awplus#
awplus(config)#
Related
loop-protection action
Commands
loop-protection timeout
show loop-protection
thrash-limiting
C613-50103-01 REV A
Parameter
ldf-interval
<period>
ldf-rx-window
<frames>
[fast-block]
for relevant conceptual, configuration, and overview
configure terminal
loop-protection loop-detect ldf-interval 5
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
Description
The time (in seconds) between successive loop-detect frames
being sent.
Specify a period between 1 and 600 seconds. The default is 10
seconds.
The number of transmitted loop detect frames whose details
are held for comparing with frames arriving at the same port.
Specify a value for the window size between 1 and 5 frames.
The default is 3 frames.
The fast-block blocks transmitting port to keep partial
connectivity.
Switching Feature Overview and