Fiber-Monitoring Action - Allied Telesis x310-26FT Command Reference Manual

X310 series stackable access switches for alliedware plus version 5.4.6-1.x
Table of Contents

Advertisement

P
C
C
LUGGABLES AND
ABLING
OMMANDS
-
FIBER
MONITORING ACTION

fiber-monitoring action

Overview
Use this command to specify an action to be taken if the optical power received on
the port changes from the baseline by the amount specified in the
fiber-monitoring sensitivity command.
Use the no variant of this command to remove the specified action or all actions
from the port.
fiber-monitoring action {trap|shutdown}
Syntax
no fiber-monitoring action [trap|shutdown]
Default
By default a log message is generated, but no additional action is performed.
Mode
Interface Configuration mode for a fiber port.
Usage
If fiber monitoring is enabled and this command is not used to set an action, a
change in received power on a fiber port only generates a log message.
Example
To set the device to send an SNMP notification when ports 1.0.1 or 1.0.2 receive
reduced power, use the commands:
awplus(config)#
awplus(config-if)#
To set the device to send an SNMP notification and to shut down the port when
ports 1.0.1 or 1.0.2 receive reduced power, use the commands:
awplus(config)#
awplus(config-if)#
To set the device not to send an SNMP notification when ports 1.0.1 or 1.0.2 receive
reduced power, use the commands:
awplus(config)#
awplus(config-if)#
To set the device not to perform any action when it receives reduced power on
ports 1.0.1 or 1.0.2, use the commands:
awplus(config)#
awplus(config-if)#
Related
fiber-monitoring sensitivity
Commands
show system fiber-monitoring
C613-50103-01 REV A
Parameter
Description
trap
Send an SNMP notification.
shutdown
Shutdown the port.
interface port1.0.1-1.0.2
interface port1.0.1-1.0.2
interface port1.0.1-1.0.2
interface port1.0.1-1.0.2
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
fiber-monitoring action trap
fiber-monitoring action trap shutdown
no fiber-monitoring action trap
no fiber-monitoring action