Log Console Exclude - Allied Telesis x310-26FT Command Reference Manual

X310 series stackable access switches for alliedware plus version 5.4.6-1.x
Table of Contents

Advertisement

L
C
OGGING
OMMANDS

LOG CONSOLE EXCLUDE

log console exclude
Overview
Use this command to prevent specified log messages from being sent to the
console, when console logging is turned on. You can exclude messages on the
basis of:
Use the no variant of this command to stop excluding the specified messages.
log console exclude [level <level>] [program <program-name>]
Syntax
[facility <facility>] [msgtext <text-string>]
no log console exclude [level <level>] [program <program-name>]
[facility <facility>] [msgtext <text-string>]
Parameter
Description
level
Exclude messages of the specified severity level.
<level>
The severity level to exclude. The level can be specified as one of the following numbers or
level names, where 0 is the highest severity and 7 is the lowest severity:
0|emergencies
1|alerts
2|critical
3|errors
4|warnings
5|notices
6|informational
7|debugging
program
Exclude messages from a specified program.
<program-
The name of a program. Either one of the following predefined program names (not
name>
case-sensitive), or another program name (case-sensitive) that you find in the log output.
rip
ripng
ospf
ospfv3
rsvp
C613-50103-01 REV A
the priority/severity of the message
the program that generated the message
the logging facility used
a sub-string within the message, or
a combination of some or all of these.
System is unusable
Action must be taken immediately
Critical conditions
Error conditions
Warning conditions
Normal, but significant, conditions
Informational messages
Debug-level messages
Routing Information Protocol (RIP)
Routing Information Protocol - next generation (RIPng)
Open Shortest Path First (OSPF)
Open Shortest Path First (OSPF) version 3 (OSPFv3)
Resource Reservation Protocol (RSVP)
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x