spanning-tree errdisable-timeout enable

Overview
Use this command to enable the errdisable-timeout facility, which sets a timeout
for ports that are disabled due to the BPDU guard feature.
Use this command for RSTP or MSTP.
Use the no variant of this command to disable the errdisable-timeout facility.
spanning-tree errdisable-timeout enable
Syntax
no spanning-tree errdisable-timeout enable
Default
By default, the errdisable-timeout is disabled.
Mode
Global Configuration
Usage
The BPDU guard feature shuts down the port on receiving a BPDU on a
BPDU-guard enabled port. This command associates a timer with the feature such
that the port is re- enabled without manual intervention after a set interval. This
interval can be configured by the user using the
interval
awplus#
Example
awplus(config)#
Related
show spanning-tree
Commands
spanning-tree errdisable-timeout interval
spanning-tree portfast bpdu-guard
C613-50103-01 REV A
command.
configure terminal
spanning-tree errdisable-timeout enable
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
spanning-tree errdisable-timeout