Diagnostics
16
Inspect the port state and LED status for all ports with an attention indicator.
1. At the Hardware View, double-click the port graphic with the attention
2. Inspect the Operational State field at the Port Properties dialog box, and the
3.
Table 12: Port Operational and LED States (HAFM appliance)
Operational State
Offline
Not Operational
Testing
Testing
Beaconing
Invalid Attachment
Link Reset
Link Incident
Segmented E_Port
17
A link incident may have occurred, but the LIN alerts option is not enabled for the
port and the attention indicator does not appear.
At the Hardware View, click Logs > Link Incident Log. The Link Incident Log
displays. If a link incident occurred, the affected port number is listed with one of
the following messages.
98
indicator. The Port Properties dialog box displays.
emulated green and amber LEDs adjacent to the port at the Hardware View.
Table 14
lists LED and port operational state combinations and associated
MAP 0600 (or other) steps that describe fault isolation procedures.
Link interface incident - implicit incident
Link interface incident - bit-error threshold
exceeded
Green LED
Amber LED
Off
Off
Off
Off
Off
Blinking
On
Blinking
Off or On
Blinking
On
Off
Off
Off
Off
Off
On
Off
Action
Go to
step
19.
Go to
step
19.
Internal loopback test in
process. Exit MAP.
External loopback test in
process. Exit MAP.
Go to
step
20.
Go to
step
22.
Go to
step
33.
Go to
step
34.
Go to
MAP 0700: Fabric,
ISL, and Segmented Port
Problem
Determination.
Edge Switch 2/24 Service Manual