Rep 10.1.1 Iit Platen Cover - Xerox WorkCentre 5020 Service Documentation

Hide thumbs Also See for WorkCentre 5020:
Table of Contents

Advertisement

REP 10.1.1 IIT Platen Cover

Parts List on PL 10.1
Removal
To avoid personal injury or electrical shock, ensure that the machine is completely off
before disassembling or adjusting. Turn OFF the power and unplug the machine.
1.
Remove the Platen Cover (PL 10.1) (Figure 1) by lifting it straight up.
Platen Cushion
When installing a new Platen
Cushion, place it against this
corner
Initial Issue
WorkCentre 5020
WARNING
Platen Cover
mounting posts
Figure 1
Replacement
NOTE: The Platen Cover comes as a kit, consisting of a Platen Cover and a Platen Cushion
(Figure 1).
1.
Place the Platen Cushion on the Platen Glass, with the adhesive strips facing up.
2.
Remove the backing from the adhesive strips.
3.
Position the Platen Cushion against the back left corner of the Platen Glass (Figure 1).
4.
Insert the mounting posts (Figure 1) of Platen Cover into the mounting holes.
5.
Carefully lower the Platen Cover down onto the Platen Cushion. Press down evenly to
ensure good adhesion.
July, 2007
4-65
Repairs and Adjustments
REP 10.1.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents