10 Error Messages

10.1 DSP Error Messages NC Software 280 470-xx, 280 472-xx, 280 474-xx

10.1.1 Non-Axis-Specific DSP Error Messages with Error Code

Error message
DSP ERROR FF01
DSP ERROR FF02
DSP ERROR FF03
DSP ERROR FF04
DSP ERROR FF05
DSP ERROR FF06
DSP ERROR FF07
DSP ERROR FF09
DSP ERROR FF0A
DSP ERROR FF0B
DSP ERROR FF0C
DSP ERROR FF0D
DSP ERROR FF0E
DSP ERROR FF0F
DSP ERROR FF10
DSP ERROR FF11
DSP ERROR C001
DSP ERROR C002
DSP ERROR C003
DSP ERROR C004
DSP ERROR C005
DSP ERROR C006
DSP ERROR C007
DSP ERROR C009
December 2001
DSP Error Messages NC Software 280 470-xx, 280 472-xx, 280 474-xx
Cause of error, corrective action
Undefined error, no traceable cause (data processing error) 280 470-01,
Host command not recognized, not valid (data processing
error)
Host and DSP watchdogs disagree (data processing error)
Undefined interrupt (data processing error)
Unknown hardware ID (hardware and software
incompatible)
No V_NOML value received from host (data processing
error)
AC fail (power module error)
Stack overflow (data processing error)
Triangular signal pulse-width modulation (hardware
problem or wrong value in MP2180)
Error upon memory request (data processing error)
No velocity control interrupt (data processing error)
Checksum error, code (data processing error)
Timeout of the speed interrupt (data processing error)
Error when initializing a software timer (data processing
error)
Error during LSV2 transmission (data processing error)
Drive start without previous synchronization (data
processing error)
Undefined error, no traceable cause (data processing error) 280 474-04
Host command not recognized, not valid (data processing
error)
Host and DSP watchdogs disagree (data processing error)
Undefined interrupt (data processing error)
Unknown hardware ID (hardware and software
incompatible)
No V_NOML value received from host (data processing
error)
AC fail (power module error)
Stack overflow (data processing error)