Chapter 5
Setup and Configuration
Section 5.21.10.2

Adding a Message Digest Key

To add a message digest key to an OSPF routing interface, do the following:
Change the mode to Edit Private or Edit Exclusive.
1.
2.
Navigate to routing » dynamic » ospf » interface » {name} » message-digest-key, where {name} is the
name of the routing interface.
3.
Click <Add message-digest-key>. The Key Settings form appears.
Figure 620: Key Settings Form
1. Key ID Box
2. Add Button
4.
Configure the following parameter(s) as required:
Parameter
Key ID
Click Add to add the key. The Message Digest form appears.
5.
Figure 621: Message Digest Form
1. Password (Key) Box
6.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
7.
Click Exit Transaction or continue making changes.
536
1
Description
The key ID.
1
RUGGEDCOM ROX II
User Guide
2
Adding a Message Digest Key