Chapter 5
Setup and Configuration
Click Exit Transaction or continue making changes.
5.
Section 5.23.3

Managing Out-Interfaces

The following sections describe how to configure and manage out-interfaces:
Section 5.23.3.1, "Viewing a List of Out-Interfaces"
Section 5.23.3.2, "Adding an Out-Interface"
Section 5.23.3.3, "Deleting an Out-Interface"
Section 5.23.3.1

Viewing a List of Out-Interfaces

To view a list of out-interfaces, navigate to routing » multicast » static » mcast-groups » {group} » out-
interface, where {group} is the name of the multicast group. If out-interfaces have been configured, the
Outgoing Interfaces table appears.
Figure 644: Outgoing Interfaces Table
If no out-interfaces have been configured, add groups as needed. For more information about adding out-
interfaces, refer to
Section 5.23.3.2, "Adding an
Section 5.23.3.2

Adding an Out-Interface

To add an out-interface, do the following:
1.
Change the mode to Edit Private or Edit Exclusive.
2.
Navigate to routing » multicast » static » mcast-groups » {group} » out-interface, where {group} is the
name of the multicast group
3.
Click <Add out-interface> in the menu. The Key settings form appears.
552
Out-Interface".