Chapter 5
Setup and Configuration
Figure 865: LLDP Form
1. Enabled Check Box
Delay Box
6. Notification Interval Box
3.
Configure the following parameter(s) as required:
Parameter
Enabled
Transmission Interval (sec)
Transmission Hold
Reinitialization Delay (sec)
750
1
2
3
4
5
6
2. Transmission Interval Box
Description
Default: true
Enables the Link Layer Discovery Protocol (LLDP). Note that LLDP is enabled on a port
when LLDP is enabled globally and along with enabling per port setting in the Port LLDP
Parameters menu.
Default: 30
The interval at which Link Layer Discovery Protocol (LLDP) frames are transmitted on
behalf of this LLDP agent.
Default: 4
The multiplier of the Tx Interval parameter that determines the actual time-to-live (TTL)
value used in an LLDPDU. The actual TTL value can be expressed by the following
formula: TTL = MIN(65535, (Tx Interval * Tx Hold))
Default: 2
The delay in seconds from when the value of the Admin Status parameter of a particular
port becomes 'Disbled' until re-initialization will be attempted.
3. Transmission Hold Box
4. Reinitialization Delay Box
RUGGEDCOM ROX II
User Guide
5. Transmission
Configuring LLDP