Viewing A List Of Pim-Sm Interfaces - Siemens RX1500 User Manual

Ruggedcom rox ii series
Hide thumbs Also See for RX1500:
Table of Contents

Advertisement

Chapter 5
Setup and Configuration
Figure 647: PIM-SM Configuration Form
1. Enable PIM-SM Check Box
3.
Configure the following parameters as required:
Parameter
Enable PIM-SM
Default Preference
Default Metric
Broken Cisco Checksum
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5.
Click Exit Transaction or continue making changes.
Section 5.24.3

Viewing a List of PIM-SM Interfaces

To view a list of PIM-SM interfaces, navigate to routing » multicast » dynamic » pim-sm » interface. If PIM-SM
interfaces have been configured, the Interface table appears.
556
1
2
3
4
2. Default Preference Box
Description
Enable PIM-SM service.
Default: 1024
Default preference value. Preferences are used by assert elections to determine
upstream routers.
Default: 1024
Default metric value. Metric is the cost of sending data through interface.
If your RP is a cisco and shows many PIM_REGISTER checksum errors from this
router, setting this option will help.
3. Default Metric Box
4. Broken Cisco Checksum Check Box
RUGGEDCOM ROX II
User Guide
Viewing a List of PIM-SM Interfaces