Chapter 5
Setup and Configuration
Parameter
value
5.
On the Set form, configure the following parameters as required:
Parameter
Local Preference
next-hop
origin
originator-id
weight
6.
Add pre-pended and/or excluded autonomous system paths. For more information, refer to
"Adding a Prepended Autonomous System Path Filter"
Autonomous System Path
7.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
8.
Click Exit Transaction or continue making changes.
Section 5.19.4
Managing Prepended and Excluded Autonomous System
Paths
The following sections describe how to configure and manage prepended and excluded autonomous system
paths:
Section 5.19.4.1, "Viewing a List of Prepended Autonomous System Path Filters"
Section 5.19.4.2, "Viewing a List of Excluded Autonomous System Paths"
Section 5.19.4.3, "Adding a Prepended Autonomous System Path Filter"
Section 5.19.4.4, "Adding an Excluded Autonomous System Path filter"
Section 5.19.4.5, "Deleting a Prepended Autonomous System Path Filter"
Section 5.19.4.6, "Deleting an Excluded Autonomous System Path Filter"
448
Description
Set , add or subtract the metric value.
Prerequisite: Operation must be empty when value is not configured.
Value.
Prerequisite: value must be empty when operation is not configured.
Description
Local preference.
Synopsis: peer
The next hop address (xxx.xxx.xxx.xxx/xx or peer to use peer address).
Synopsis: egp, igp, incomplete
The origin code.
This parameter is not supported and any value is ignored by the system.
Weight.
filter".
and/or
Section 5.19.4.4, "Adding an Excluded