Configuring A Set - Siemens RX1500 User Manual

Ruggedcom rox ii series
Hide thumbs Also See for RX1500:
Table of Contents

Advertisement

Chapter 5
Setup and Configuration
Parameter
Prefix List
5.
On the Match Advertising Source Address form, configure the following parameters as required:
Parameter
Prefix List
6.
On the Match form, configure the following parameters as required:
Parameter
AS Path Filter
Metric
Peer Address
Origin
7.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
8.
Click Exit Transaction or continue making changes.
Section 5.19.3.8

Configuring a Set

To configure matched rules for a route map filter entry, do the following:
1.
Change the mode to Edit Private or Edit Exclusive.
2.
Navigate to routing » dynamic » bgp » filter » route-map » {tag} » entry » {number} » set, where {tag} is
the tag for the route map filter and {number} is the sequence number for the entry. The Aggregator, Metric
and Set forms appear.
Figure 497: Aggregator Form
1. AS Number Box
446
Description
The prefix list name.
Description
The prefix list name.
Description
Match the BGP AS path filter.
Match the route metric.
This parameter is not supported and any value is ignored by the system.s
Synopsis: egp, igp, incomplete
Match the BGP origin code.
1
2
2. IP Address Box
RUGGEDCOM ROX II
User Guide
Configuring a Set

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rx1501Rx1510Rx1511Rx1512

Table of Contents