Figure 400: Ingress Source Ports Table
If no ingress source ports have been configured, add ingress source ports as needed. For more information, refer
to
Section 5.16.3.2, "Adding an Ingress Source
Section 5.16.3.2

Adding an Ingress Source Port

To add an ingress source port for port mirroring, do the following:
1.
Change the mode to Edit Private or Edit Exclusive.
2.
Navigate to switch » port-mirroring » ingress-src and click <Add ingress-src>. The Key Settings form
appears.
Figure 401: Key Settings Form
1. Ingress Source Slot List
3.
Configure the following parameter(s) as required:
Parameter
Ingress Source Slot
Ingress Source Port
4.
Click Add to create the new ingress source port.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
5.
to proceed.
6.
Click Exit Transaction or continue making changes.
Adding an Ingress Source Port
Port".
1
2. Add Button
Description
Synopsis: sm, lm1, lm2, lm3, lm4, lm5, lm6
The name of the module location provided on the silkscreen across the top of the
device.
The selected ports on the module installed in the indicated slot.