Chapter 4
System Administration
Figure 205: Alarm Configuration Form
1. Description Box
6. Auto Clear Check Box
3.
Configure the following parameters as required:
Parameter
description
severity
admin-enable
failrelay-enable
led-enable
auto-clear
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5.
Click Exit Transaction or continue making changes.
194
1
2
3
4
5
6
2. Severity List
3. Admin Enable Check Box
Description
The name of the alarm.
Synopsis: emergency, alert, critical, error, warning, notice, info, debug
The severity level can be one of emergency, alert, critical, error, warning, notice, info,
and debug. This cannot be changed for some alarms.
If disabled, the alarm is not reported in the active list and does not actuate LED/failrelay.
If enabled, this alarm will assert the failrelay.
If enabled, the main 'Alarm' LED light will be red when this alarm is asserted. If disabled,
the main 'Alarm' LED light is not affected by this alarm.
If enabled, the LED and failrelay will be cleared automatically when condition is met.
4. Failrelay Enable Check Box
RUGGEDCOM ROX II
User Guide
5. LED Enable Check Box
Configuring an Alarm