1.
Open the Front Cover.
2.
Remove the Fuser (page 8-12).
3.
Remove the Rear Cover (page 8-18).
4.
Remove the Bottom Cover (page 8-19).
5.
Remove the Right Pole Inner Cover (page 8-21).
6.
Remove the Right Pole Cover (page 8-22).
7.
Remove the Right Cover (page 8-23).
8.
Remove the Left Pole Inner Cover (page 8-24).
9.
Remove the Left Pole Cover (page 8-25).
10.
Remove the Left Cover (page 8-26).
11.
Remove the Top Cover (page 8-27).
Note
When performing the following step, it is not necessary to disconnect the
Interlock Switch.
12.
Remove the Interlock Switch (page 8-82).
13.
Remove 2 screws (10 mm) securing the Fuser Bracket (PL6.1.12) to the
printer.
Caution
DO NOT separate the Fuser Bracket and the printer too far apart,
because they are connected by a wiring harness.
14.
Remove the Fuser Bracket.
15.
Release the Main Drive wiring harness from the Main Drive Duct
(PL8.1.9).
16.
Remove 1 screw (10 mm) securing the Main Drive Duct to the printer.
17.
Release the notches on the Main Drive Duct and slide the Main Drive
Duct backward to remove it.
18.
Disconnect the following 4 connectors:
Main Motor - P/J211
Sub Motor - P/J221
Developer Motor - P/J222
Exit Clutch: P/J2761