Phaser 6180MFP Multifunction Printer Service Manual
11.
Open the Tray 1 (MPT) Cover (PL1.2.26).
12.
Release the hook of the Shaft Pivot (PL1.2.10) on the left and right side of
the Front Cover. Pull the Shaft Pivot outward while holding the Front
Cover and remove the Cover from the Left (PL7.1.3) and Right Links (PL
7.1.13).
13.
Release the hooks of the Tray 1 (MPT) Shaft Pivot (PL1.2.33) securing
the Front Cover and the MPT Cover to the printer and pull out the MPT
Shaft Pivot.
14.
Remove the Front Cover together with the Tray 1 (MPT) Cover.
Shaft Pivots
Shaft Pivots
Replacement Note
Replacement Note
Be sure to tilt the Front Cover accordingly when mounting the Front
Cover. Push the Shaft Pivot in all the way to secure the hooks of the
Shaft Pivots to the Left and Right Links.
Service Parts Disassembly
Left Link
Right
Link
s6180mfp-216
8-29