Error Messages and Codes
Download Mode
3-118
Error has occurred while updating MCU firmware. The following
troubleshooting procedure applies to this error.
Applicable Chain Link
Chain Link
Error)
Initial Actions
Cycle printer power.
If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
MCU Board, PL9.2.13
Troubleshooting Procedure Table
Step
Actions and Questions
1. Check the firmware version:
1
>
Configuration.
2. Does the firmware have the correct
version?
2
1. Check the MCU Board for correct
installation. Reseat the MCU Board
(page 8-88).
2. Does the error still occur?
024-360: Download Mode, Send FW Data (MCU Download
System
Information Pages
>
Phaser 6180MFP Multifunction Printer Service Manual
Wiring and Plug/Jack Map References
Yes
Go to step 2.
Replace the
MCU Board
(page 8-88).
No
Update the
firmware
("Firmware
Update" on
page A-3).
Complete.