REP 10.4 Exit Drive Assembly
Parts List on
PL 10.20
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Before performing this procedure, refer to General Disassembly Precautions,
1.
Remove the rear cover,
PL 28.10 Item
2.
Remove the fuser fan duct,
PL 4.15 Item
WorkCentre 4150/4250/4260WorkCentre WorkCentre 4150/4250/42604150/
WARNING
CAUTION
GP
6.
19.
3.
Remove the Exit Drive Assembly
NOTE: The position of each screw is numbered 1 to 4 on the Mounting Plate. Remove the
screws in reverse numerical order.
10.
2
Remove the four numbered mounting
screws in reverse order.
Replacement
NOTE: Reinstall the 4 screws that secure the exit drive assembly in numerical order.
1.
Replacement is the reverse of the removal procedure.
January 2016
4-151
(Figure
1).
1
Disconnect the three connectors.
3
Remove the Exit
Drive Assembly.
Figure 1 Removing the Exit Drive Assembly
Repairs and Adjustments
REP 10.4