Deve Motor Error - Xerox Phaser 6180MFP Service Manual

Multifunction printer
Hide thumbs Also See for Phaser 6180MFP:
Table of Contents

Advertisement

Error Messages and Codes

Deve Motor Error

3-134
The Deve Motor has failed. The following troubleshooting procedure applies to
this error.
Applicable Chain Link
Chain Link
Initial Actions
Cycle printer power.
If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
Feeder Kit, PL3.2.1
Main Drive, PL8.1.2
MCU Board, PL9.2.13
Right Side Harness, PL10.1.12
Troubleshooting Procedure Table
Step
Actions and Questions
1. Check the Print Cartridges for
1
correct installation.
2. Are the Print Cartridges correctly
installed?
2
Does the error still occur when the
printer is turned On?
1. Check the wiring harness
3
connectors P/J22 and P/J222
between the MCU Board and the
Main Drive.
2. Are the connectors securely
connected?
1. Perform the Deve Motor test
4
(page 4-57):
Printer Diag
Test
Door while running the test.
2. Does the Motor operate properly?
093-320: Deve Motor Error (IOT Motor Failure)
Wiring and Plug/Jack Map References
page 10-10
page 10-13
Service Mode
>
>
Engine Diag
>
Motor
>
Deve
Motor. Close the Front
Phaser 6180MFP Multifunction Printer Service Manual
"Map 1 - Electrical and Drive" on
"Map 4 - LVPS and MCU Board" on
"Main Drive" on page 10-28
Yes
No
Go to step 3.
Reseat the Print
Cartridges
(page 8-11).
Go to step 2.
Go to step 3.
Complete.
Go to step 4.
Reconnect the
connectors.
Go to step 4.
Replace the
Go to step 5.
MCU Board
(page 8-88).