General Troubleshooting
4-46
CRU Sensor M (Magenta Toner Cartridge Sensor)
Caution
When performing this procedure, remove and cover the Print Cartridges
to avoid exposure to light if the Front Door will be opened for prolonged
periods.
1.
Enter the Service Diagnostic menu (page 4-5).
2.
Open the Front Cover.
3.
Remove the Transfer Unit (page 8-9).
4.
Remove the Print Cartridges (page 8-11).
5.
Perform the CRU Sensor M test:
Test
>
CRU Sensor M
6.
Install and remove the Magenta Print Cartridge while checking the
information on the Control Panel display. The Low and High values
change from 0 up to 99.
Control Panel
7.
Press the Stop button to stop the CRU Sensor M test.
> OK.
Normal
CRU Sensor M
L-0
Phaser 6180MFP Multifunction Printer Service Manual
Printer Diag
>
Engine Diag
CRU Sensor M
H-0
>
Sensor
s6180mfp-165