Phaser 6180MFP Multifunction Printer Service Manual
17.
Remove the 2 Clamps on the Fuser wiring harness from the Earth Frame
Assembly.
18.
Disconnect the Laser Unit connector P/J12 from the MCU Board
(PL9.2.13) and remove the Ferrite Core (PL5.1.13) from the harness.
19.
Release the Laser Unit wiring harness from the 3 clamps and pull the
wiring harness from the hole of the printer.
Clamp
Clamps
Service Parts Disassembly
P/J12
Ferrite
s6180mfp-286
8-53