Chapter 12
F-12-99
2) Disconnect the connector [1], and detach the
control panel [2].
F-12-100
12.5.16.4
Removing
Control Panel Back Plate
1) Disconnect the 3 connectors [1] from the CPU
PCB, remove the 2 flat cables [2], disconnect the 2
connectors [3] from the inverter PCB, remove the
binding screw [4], and remove the 8 self-tapping
screws [5]; then, detach the control panel back plate
[6].
12-38
the
0006-2163
F-12-101
12.5.16.5
Removing
Control Panel Inverter PCB
1) Disconnect the 3 connectors [1], and remove the 4
screws [2]; then, detach the control panel inverter
PCB [3].
F-12-102

12.5.17 Environment Sensor

12.5.17.1 Pressure Release of
the
Intermediate
Unit
1) Open the front cover, and turn the intermediate
transfer unit releasing lever to unlock it.
the
0000-5186
Transfer
0006-2169