Download Print this page
Canon iR5570 Service Bulletin
Canon iR5570 Service Bulletin

Canon iR5570 Service Bulletin

Copier b/w hardware
Hide thumbs Also See for iR5570:

Advertisement

Quick Links

Model:
iR5570
iR6570
Location:
Laser Scanner Unit
Subject:
Correcting light images and fogging
Particulars:
<Symptom>
The printout may show any of the following symptoms: the entire image is too light; the area in the middle in
sub scanning direction is foggy; the image along the edge in sub scanning direction is too light.
Cause
1. Condensation occurred inside the machine (e.g., as when the machine is turned on immediately after it has
been moved from a low to normal temperature environment as from a warehouse to an office or after it has been
left without power for a long time).
2. The laser scanner unit has become displaced because of vibration/ impact occurring while the machine is
moved.
Factory Remedy
The following will be implemented to prevent displacement of the laser scanner unit:
1. Change the part used to keep the laser unit in place to increase its retention power (pressure).
2. Change the configuration of engagement between the scanner unit and the machine.
Service Bulletin
Issued by Canon Europa N.V.
Ref No.:
iR6570-002
(F1-T01-0M5-10008-01)
Date:
May, 2005
COPIER B/W
HARDWARE
(1/5)

Advertisement

loading

Summary of Contents for Canon iR5570

  • Page 1 Service Bulletin COPIER B/W Issued by Canon Europa N.V. HARDWARE Model: Ref No.: iR5570 iR6570-002 iR6570 (F1-T01-0M5-10008-01) Date: May, 2005 Location: Laser Scanner Unit Subject: Correcting light images and fogging Particulars: <Symptom> The printout may show any of the following symptoms: the entire image is too light; the area in the middle in sub scanning direction is foggy;...
  • Page 2 iR6570-002 Points to Note About Servicing: Go through the following if any of the foregoing symptoms has occurred: 1. Eliminate condensation inside the machine: 1-1. Set the environment switch (drum/ non-interruptive switch) to ON (default: OFF). 1-2. Set "1" to the following in service mode (Level 2): COPIER>OPTION>BODY>DRUM-H-SW (default: "0").
  • Page 3 iR6570-002 <Points to Note When Mounting the Scanner Unit> 1) To eliminate condensation inside the machine, it is important that the drum heater is kept ON while remounting the scanner unit. Be sure to go through the shut-down instructions when turning off the power. 2) When fitting the laser scanner unit in the machine, be sure to push the top [A] of the unit with your fingers and push it until it butts against the rear.
  • Page 4 iR6570-002 2-9. Set "1" to the following in service mode: COPIER>FUNCTION>DPC>DPC (to force execution of potential control). 2-10. Hold down the control panel power switch for 3 seconds or more. 2-11. Go through the down-sequence instructions on the screen so that the main power switch may be turned off.
  • Page 5 iR6570-002 4. Replace the developing assembly. 4-1. For instructions on disassembly and assembly, see the section "Removing the Developing Assembly" in the Service Manual. 5. Check the images. 5-1. Check the images as in step 3. 5-2. If the images are free of the foregoing symptoms, go to step 6. Otherwise, go to step 6 and then check other possible causes.
  • Page 6 Flow of Work: Correcting Image Faults in the iR6570/5570 · Entire image too light · Area in middle foggy · Image along edge too light Drum heater ON Check laser Replace developing power assembly (220 or NO (221 or higher) lower) Re-mount laser Suspect other...