16.3.4.7.13 PS-C1: Screen does not change while 'Please Wait' screen keeps displaying
[ Verified by Canon Inc. ]
Field Remedy
When 'Please Wait' screen appears, it does not change until pressing Close button. This symptom has been
corrected with a combination of the PS-C1 system Ver.1.1.1 and iRC3200 system Ver.10.01 so that the next
screen will automatically appear without pressing Close button.
16.3.4.7.14 PS-C1: Not start up after turning power of host machine OFF/ON
[ Verified by Canon Inc. ]
Field Remedy
If only the host machine is turned OFF/ON, it is possible that the system of PS-C1 does not start up normally.
This symptom has been corrected with the PS-C1 system Ver.1.1.1, so upgrade it to Ver.1.1.1 or later if this
happens.
16.3.4.7.15 PS-C1: Machine locking up (hanging up/nonoperational) after forcibly outputting paper
[ Verified by Canon Inc. ]
Field Remedy
After a paper size error occurs during printing, if the job is forcibly output through an operation on the host
machine control panel, PS-C1 can lock up. This symptom has been corrected with the PS-C1 system Ver.1.1.1,
so upgrade it to Ver.1.1.1 and later if this happens.
16.3.4.7.16 PS-C1: PS error when outputting image prepared with PhosoShop6 on Mac OS9
[ Verified by Canon Inc. ]
Field Remedy
When attempting to output the binary mode image file prepared with PhosoShop6 on Mac OS9, PS error might
occur. This symptom has been corrected with the PS-C1 system Ver.1.1.1, so upgrade it to Ver.1.1.1 or later if
this happens.
16.3.4.7.17 Reader unit does not operate after startup
[ Case in the field ]
< Field Remedy >
In the field, this symptom occurred because the flat cables between the Reader Controller PCB and the Interface
PCB were not securely fitted. Unplug and reinsert it.
Interface PCB: J307, J308
Reader Controller PCB: J202, J203
16.3.4.7.18 FAX board cannot be detected even although it is replaced
[ Case in the field ]
< Field Remedy >
In the field, this symptom occurred because the Main Controller PCB (Sub) was faulty. Unplug and reinsert the
connectors (particularly J1309 and J1336) on it. If the symptom still recurs, replace it with a new one.
Main Controller PCB (Sub): FG3-2855