E602-0001/E602-0002/E602-0003 Error Code: Remedy Upon Occurrence Of Error Code - Canon iR C3200 Series Service Manual

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

Chapter 16
If the maximum density areas at 'THRU 0' are the same as those of 'THRU 1', carry out user mode > adjust/
cleaning > automatic gradation correction > full correction.
*Make a test copy. If the correct density is produced, the procedure is finished.
*If the correct density is not produced, go to step 5.
5 In service mode level 2 COPIER > DISPLAY > DENS > CHG-DC-Y/M/C/K, check the Vd value.
6Again, in in service mode level 1 COPIER > TEST > PG > THRU, set 0 (default) and 1. With each setting,
output service mode level 1 COPIER > TEST >PG > TYPE=14.
If 'THRU 0' is faint, adjust in service mode level 2 COPIER > ADJUST > V-CONT > VCONT-Y/M/C/K (1
unit: 10V). If the image is faint, increase the value.
Input a value that is 650V or lower when added to the the original value (as displayed in CHG-DC-Y/M/C/K)
by VCONT. If this value is exceeded, E061-0xdd will be generated and then the full correction performed in
step 7 will be disabled.
7 Perform user mode > adjustment/ cleaning> automatic gradation correction> full correction.
16.3.10.84
E602-0001/E602-0002/E602-0003 Error Code: Remedy upon
occurrence of error code
[ Manual-related ]
Description
The captioned error codes are displayed when:
a. E602-0001: the host machine detects that the system is not properly installed in the HDD when the HDD starts
up.
b. E602-0002: the host machine detects an error during reading the data from the HDD when the HDD starts up.
c. E602-0003: there occurs a discrepancy between the control data for the data stored in the HDD and the actual
data. (HDD sector Write Abort)
Field Remedy
a. E602-0001
Check a connection between the HDD and the Main Controller PCB. If there is no problem, replace the HDD with
a new one and reinstall the system software.
Or, replace the Main Controller PCB with a new one if it is faulty.
b. E602-0002
Reinstall the system software.
c. E602-0003
There are four partitions inside the HDD. The following are solutions depending on in which sector a write abort
occurs.
c-1. Write Abort in Image Storage Area
Turn the power OFF/ON, which can recover errors automatically.
c-2. Write Abort in other areas than Image Storage Area
c-2-1. If you can enter service mode:
c-2-1-1. In service mode [COPIER> Function> STSTEM> CHK-TYPE], select "0" and perform [HD-CHECK].
The required time depends on a capacity of the HDD, usually approximately 20 to 40 minutes.
c-2-1-2. Turn the power OFF/ON to make sure that the machine starts up normally.
c-2-1-3. If no, perform [HD-CLEAR] by selecting "1" and "2".
c-2-1-4. Reinstall the system software.
16-162
0002-1761

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir c3220n prt

Table of Contents