Chapter 16
Description
Detail
0110
0210
0310
0410
16.3.10.34 E110-0x10 Error Code
[ Case in the field ]
Field Remedy
E110-0x10 can be displayed when the rotational failure of the laser scanner motor has been detected.
1. Swap the affected laser unit with others.
2. Check whether or not the sub code of E110 will be changed.
- If the sub code is changed, the laser unit is faulty. So, replace it with a new one.
- If the sub code is not changed, it is possible that the DC controller PCB is faulty. So, replace it with a new
one. In the field, replacement of the DC controller PCB solved the problem.
DC controller PCB: FG3-3003 (100V), FG3-2356 (120/220/240V)
Laser Unit: FG6-8962
16-138
Description
The rotation of the Y laser
scanner motor is faulty.
The rotation of the M laser
scanner motor is faulty.
The rotation of the C laser
scanner motor is faulty.
The rotation of the K laser
scanner motor is faulty.
T-16-10
Timing of detection
The motor lock signal remains in an unlock
state for 1 sec or more while the laser scanner
motor is in operation.
The motor lock signal remains in an unlock
state for 1 sec or more while the laser scanner
motor is in operation.
The motor lock signal remains in an unlock
state for 1 sec or more while the laser scanner
motor is in operation.
The motor lock signal remains in an unlock
state for 1 sec or more while the laser scanner
motor is in operation.
0004-8993