Code
Detail
Description
0004
There is a fault in data
communication. The cassette
pedestal controller or the finisher
controller PCB is faulty.
E716
There is a fault in the communication between the cassette pedestal and the printer unit.
0000
There is a fault in data
communication. The DC
controller or the cassette pedestal
controller PCB is faulty.
E717
The communication with the NE controller is faulty.
0000
0001
0002
E719
The coin vendor is faulty.
0000
0001
0002
Timing of detection
The communication between the
finisher and the machine is
disrupted.
An attempt at recovery fails for 2
sec or more after the
communication between the
cassette pedestal and the machine
has failed.
The communication with the NE
controller is disrupted and is not
resumed within 3 sec thereafter.
While the new controller is starting
up, an error occurs. (Detection was
normal before the power has been
turned off, but detection fails when
the power is turned o)
While the new controller is in
operation, an IPC error occurs (The
system assumes that IPC
communication cannot be restored.)
The coin vendor cannot be detected
at startup.
While the coin manager is starting
up, an error occurs. (Detection was
normal before the power has been
turned off, but detection fails when
the power is turned on.)
While the coin manager is in
operation, an error occurs. (The
system assumes that IPC
communication cannot be restored,
there is an open circuit for the
pickup/delivery signal, or there is
an illegal connection.)
Chapter 17