Canon iR C3200 Series Service Manual page 982

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

Chapter 17
Code
E003
E004
17-2
Detail
Description
0004
0005
0006
0007
0008
0101
0102
The temperature of the fixing unit is abnormally low after standby.
0001
The protection circuit of the fixing unit is faulty.
0001
0002
Timing of detection
The output of the non-contact
thermistor does not reach 120 deg C
within 240 sec after it has reached
90 deg C.
The output of the non-contact
thermistor does not reach 140 deg C
within 180 sec after it has reached
120 deg C.
The output of the non-contact
thermistor does not reach 160 deg C
within 180 sec after it has reached
140 deg C.
The output of the non-contact
thermistor does not reach 180 deg C
within 180 sec after it has reached
160 deg C.
The output of the non-contact
thermistor does not reach 190 deg C
within 180 sec after it has reached
180 deg C.
The output of the non-contact
thermistor does not reach 120 deg C
within 300 sec after power-on.
The output of the non-contact
thermistor does not reach 190 deg C
within 300 sec after it has reached
120 deg C.
After standby, the reading of the
non-contact thermistor remains 120
deg C or less for 10 sec.
A short circuit of the triac is
detected fo 500 msec continuously.
An open circuit of the temperature
detection thermistor inside the non-
contact thermistor is detected for
500 msec continuously.