16.3.10 Error Code
16.3.10.1 E000 Error code detail The rise in temperature in the fixing unit at time
of power-on is inadequate.
Symptom
E000 The rise in temperature in the fixing unit at time of power-on is inadequate. (Error code detail)
Description
Detail
0001
16.3.10.2 E001 Error code detail The fixing unit is overheating.
Symptom
E001 The fixing unit is overheating. (Error code detail)
Description
Detail
0001
0003
0004
0005
Description
After power-on, the output of the noncontact
thermistor does not reach 40°C within 180 sec.
Description
The high-temperature detection port ontinues to remain ON
for 500 msec.
The reading of the no-contact thermistor remains 250°C for
500 msec.
The difference in temperature between the non-contact
thermistor and the end thermistor remains 80°C or more for
500 msec.
At the end of initial rotation, the difference in temperature
between the sub (end) thermistor and the main (non-
contact)thermistor is 20°C or more for 100 msec.
(A reversal in temperature (caused, for
example, by a piece of residual paper) is detected.)
T-16-2
Timing of detection
T-16-3
Timing of detection
Chapter 16
0002-1288
0002-1380
16-121
Need help?