For the new delivery vertical path unit to function, the
version of the DC controller must be 3.06 or later. Be
sure to check its version in service mode:
COPIER>DISPLAY>VERSION>D-CON.
1) Slide out the fixing/feeding unit.
2) Open the delivery vertical path cover [1]; then,
remove the 2 screws [2], and detach the upper left
cover [3].
F-10-222
3) Remove the screw [1], and detach the delivery
inside cover [2]; then, detach the delivery vertical
path cover [3] from the machine.
F-10-223
4)
To detach the delivery vertical path unit, lift the unit
and then pull it out toward the front.
Disconnect the 2 concoctors [1], and remove the 4
screws [2]; then, detach the delivery path unit [3].
(The delivery path unit will no longer be used.)
F-10-224
5) Using a flat-blade screwdriver, detach the slip-stop
[2] from the delivery vertical path cover [1]; then,
detach the strap [3] from the delivery inside cover.
(The delivery vertical path cover will no longer be
used.)
F-10-225
6) Attach the strap [1] found on the delivery inside
cover to the new delivery vertical path cover [2];
then, fix it in place using the slip-stop [3].
Chapter 10
10-81