Controlling The Charging Bias - Canon iR C3200 Series Service Manual

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

9.5.4.2 Controlling the Charging Bias

AC
Component:
DC
Component:
d-1. Route of the Primary Charging Bias
High-voltage unit
level of output suited to discharge current control
level of output suited to the reading of the environment sensor/SALT
sensor
DC power supply unit
J85
J87
J76
HV1-SUB
J73
J75
J71
J72
J71
J72
HV1(Y)
HV1(M)
J70
J70
T-9-36
J91
HV2-SUB
J77
J79
J71
J72
J71
HV1(C)
HV1(Bk)
J70
J70
F-9-31
J86
J82
HV2
J81
J72
AC/DC bias for primary
charging roller
: +24V
: -1kV
Chapter 9
0000-4502
9-35