E351 Error Code Detail The Eco-Id Pcb Is Faulty; E402 Error Code Detail There Is A Fault In The Feeder Motor - Canon iR C3200 Series Service Manual

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

16.3.10.50 E351 Error code detail The ECO-ID PCB is faulty.

Symptom
E351 The ECO-ID PCB is faulty. (Error code detail)
Description
Detail
0000
16.3.10.51 E351-0000 Error Code: Because of poor connection of connector on
ECO-ID PCB
[ Inspected by Canon Inc. ]
Description
E351-0000 can be displayed when an error occurs in initial communication of the ECO-ID PCB.
Field Remedy
As a result of inspection, it was found that this symptom occurred because the connector between the ECO-ID PCB
and J1315 on the Main Controller PCB (Main) was not securely fitted. So, check the connection.

16.3.10.52 E402 Error code detail There is a fault in the feeder motor.

Symptom
E402 There is a fault in the feeder motor. (Error code detail)
Description
Detail
T-16-17
Description
There is a fault in the initial communication.
T-16-18
Description
The feeder motor (M2) fails to
rotate. The feeder motor clock
sensor (SR1) is faulty.
Timing of detection
Timing of detection
The feeder motor encoder pulse is not
detected within 0.3 sec after the DF
feeder motor drive signal has been
turned ON.
Chapter 16
0002-1651
0006-6281
0002-1653
16-145

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir c3220n prt

Table of Contents