Chapter 16
16.3.10.53 E402 Error Code
[ Case in the field ]
Description
This error code can be displayed when the feeder motor encoder pulse is not detected within 0.3 sec after the
DF feeder motor drive signal has been turned ON.
Cause
There is a case in the field that an adjustment of the ADF transfer belt solved the problem.
Field Remedy
Check whether the feeder motor (M2) and the feeder motor clock sensor (SR1) are operating normally. If there
is no problem, adjust the tension of the belt.
16.3.10.54 E404 Error code detail There is a fault in the delivery motor.
Symptom
E404 There is a fault in the delivery motor. (Error code detail)
Description
Detail
16.3.10.55 E500 Error code detail There is a fault in finisher communication.
(Finisher-N1)
Symptom
E500 There is a fault in finisher communication. (Finisher-N1) (Error code detail)
Description
Detail
16-146
Description
The face-down delivery motor
(M3) fails to rotate. The
facedown delivery motor clock
sensor (SR7) is faulty.
Description
There is a fault in data
communication.
T-16-19
Timing of detection
The face-down delivery motor encoder
pulse is not detected within 0.3 sec after
the face-down delivery motor drive
signal has been turned ON.
T-16-20
Timing of detection
The communication between the machine
and the finisher remains disrupted for 5 sec or
more.
0003-8600
0002-1656
0002-1665