Chapter 11
Component
Heat retaining heater
Main thermistor
Sub thermistor
Thermal switch
Separation claw
Fixing inlet sensor
Fixing delivery sensor
Sub heater (H2)
Main heater (H1)
11-2
Notation
Description
H3
100/120/230V:80W (no temperature control)
TH1
Non-contact type (temperature control/overheating detection)
TH2
Temperature control, overheating detection
TP1
222 -/+8 deg C (operating temperature)
Non-contact type (facilitates paper separation in high-humidity environment)
PS27
Detection of passage of paper to fixing unit)
PS25
Detection of delivery of paper after fixing
Non-contact
separation claw
Thermal switch
(TP1)
Heat retaining heater
Fixing roller
Fixing
delivery
sensor
Pressure
(PS25)
roller
Sub thermistor
Main thermistor
(TH1; non-contact)
Pressure roller
Fixing inlet guide
F-11-1
Fixing inlet
sensor
(PS27)
F-11-2
Fixing roller