E220-0000 Error Code: Scanning Lamp Did Not Light Up After Turning Power On - Canon iR C3200 Series Service Manual

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

Chapter 16
16.3.10.41 E220-0000 Error Code: Scanning lamp did not light up after turning
power ON
[ Case in the field ]
Field Remedy
E220-0000 can be displayed when the intensity detected by the CCD becomes below a specific level during
shading adjustment at time of power-ON.
Unplug and insert the flat cable connecting the CCD unit and the reader controller PCB (CCD side: J102, RCON
side: J205). If the symptom still recurs, replace the reader controller PCB with a new one because its
replacement solved the problem in the field.
Reader Controller PCB: FG3-2564 (100V), FG3-2570 (120/220/240V)
16.3.10.42 E220-0000 Error Code when turning power ON while opening platen
cover
[ Case in the field ]
< Field Remedy >
It is possible that the connectors connecting to the Interface PCB are not securely fitted. Unplug and reinsert
them on the Interface PCB.
16.3.10.43 E220-0000 Error Code: No problem with CCD unit and Reader
Controller PCB
[ Case in the field ]
Description
E220-0000 can be displayed when the intensity detected by the
CCD is below a specific level during shading adjustment at power-on.
Cause
In the field, this symptom occurred because the Inverter PCB was faulty (specifically, the fuse F1 opened.).
Field Remedy
Check continuity of the fuse F1 on the Inverter PCB. If it opens, replace the PCB with a new one.
Inverter PCB: FH3-7213