Removing The Mirror Base Home Position Sensor; Original Sensor - Canon iR C3200 Series Service Manual

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

Chapter 6
6.4.10.3 Removing the Mirror
Base Home Position Sensor
1) Disconnect the connector [1], and detach the mirror
base home position sensor [2].
F-6-82

6.4.11 Original Sensor

6.4.11.1
Removing
Copyboard Glass
1) Open the ADF or the copyboard cover.
2)
Points to Note When Removing the Copyboard
Glass
When removing the copyboard glass, take care not to
touch the surface of the glass or the white plate behind
it.
(The presence of dirt will cause lines in the images.)
If dirt is found, be sure to remove it using lint-free
paper moistened with alcohol.
6-30
0000-4410
the
0000-8281
F-6-83
F-6-84
3) Remove the 2 screws [1], and detach the right glass
retainer [2]; then, detach the copyboard glass [3].