Implementing Countermeasure Against Malfunction Of Fixing Feeder Unit Open/Closed Sensor; E004-0005 Error Code: Because Of Faulty Dc Controller Pcb - Canon iR C3200 Series Service Manual

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

Chapter 16
16.3.10.6 E004-0003 Error code Or message 'Remove the paper from the finisher
trays.': after implementing countermeasure against malfunction of fixing feeder
unit open/closed sensor
Symptom
E004-0003 or message 'Remove the paper from the finisher trays.': after implementing countermeasure against
malfunction of fixing feeder unit open/closed sensor Error Code
Description
This symptom occurs after attaching a sheet of mylar to the sensor flag for the fixing feeder unit open/closed
sensor as a countermeasure against malfunction
Cause
1. While attaching a sheet of mylar to the sensor flag, the delivery vertical path cover open/closed sensor comes
off and short-circuited due to a contact with the sheet metal. Finally, the DC fuse PCB (FG3-2337) is broken.
2. Since the face-down delivery sensor 1 comes off, a message 'Remove the paper from the finisher trays.' is
displayed.
Field Remedy
1. Replace the DC fuse PCB with a new one.
2. Reinstall the face-down delivery sensor 1.
Note: When implementing the countermeasure, be careful not to detach the face-down delivery sensor 1 and the
delivery vertical path cover open/closed sensor.

16.3.10.7 E004-0005 Error Code: Because of faulty DC Controller PCB

[ Inspected by Canon Inc. ]
Description
E004-0005 can be displayed when a short circuit of the main thermistor (TH1) is detected for 500 msec
continuously.
Cause
As a result of inspection, it was found that the DC Controller PCB was faulty.
Field Remedy
Follow the steps below:
1. Measure the electrical resistance with a tester to check whether the main thermistor is short-circuited. If so,
replace the main thermistor with a new one.
2. Inspect the cables and the connectors between the drawer connector of the fixing unit and the main thermistor
for any abnormality.
3. Inspect the cable and the connectors between J108A on the DC Controller PCB and the drawer connector deep
inside the machine for any abnormality.
4. Replace the DC Controller PCB with a new one.
- Main Thermistor: FH7-7586
- Fixing Drawer Cable Ass'y (Fixing Ass'y): FG6-9644 for 100V, FG6-9646 for 120V, FG6-9647 for 220/240V
- Fixing Drawer Cable (Host Machine): FG3-2310
- DC Controller PCB: FG3-2356
16-124
0002-4676
0006-2042