F-6-59
6.4.7.3 Removing the Fuse
PCB Unit (option; 100/230v
model only)
1) Disconnect the 2 connectors [1], ad remove the 2
screws [2]; then, remove the fuse PCB unit [3].
F-6-60

6.4.8 Scanner Motor

6.4.8.1
Removing
Copyboard Glass
1) Open the ADF or the copyboard cover.
2)
Points to Note When Removing the Copyboard
Glass
When removing the copyboard glass, take care not to
touch the surface of the glass or the white plate behind
it.
0000-4413
the
0006-7342
(The presence of dirt will cause lines in the images.)
If dirt is found, be sure to remove it using lint-free
paper moistened with alcohol.
F-6-61
F-6-62
3) Remove the 2 screws [1], and detach the right glass
retainer [2]; then, detach the copyboard glass [3].