11.4 Protective Functions

11.4.1 Turning Off the Power Against Overheating (in response to
activation of thermal switch)
Once its contact has opened, the thermal switch will not return to its initial state even after the error temperature has
been corrected. Be sure to replace it.
If the internal temperature of the thermal switch exceeds 222 -/+8 deg C, the thermal switch goes OFF to cut the
power to the fixing heater.
Fuse PCB
DC controller
PCB
J105A
J51
6
J69_7 HRLY_ON
3
J69_9 TR_ERR*
2
J69_11 H2_ON
1
J69_12 H1_ON
TP
Fixing roller
Heater control PCB
J4
J5
RL
Triac short-
circuit
Heater
drive
detection
PCB
circuit
Q10
Q23
Q11
H1
H2
F-11-15