If multiple sensors are detected at the same time, the latest detected sensor's Warning
message is provided.
The warning message continues to play the same VRS message.
To cancel the Warning message use Security Sensor Reset Service Code Program 11-12-62.
When using external speaker, a start and end tone is not provided for any situation.
If, while playing a Warning message and the targeted internal or external paging group was
already playing another Warning message, the first Warning message is canceled. In this
case either the internal or external paging group was duplicated with the latest paging
group. An old Warning message stops both internal and external paging.
If the DND key is pressed at the called terminal while playing a Watch or Warning message,
the next message is not played because the terminal is determined to be busy. When the
terminal returns to an idle state, the message is played again.
An emergency call via analog trunk which has no disconnect signal, if Program 14-02-18 is
invalid the call cannot disconnect by trunk side.
An emergency call does not provided over Aspire Net trunks.
In case of an emergency call the trunk key status is red. It is also red while monitoring or
speaking.
An emergency call goes through even if no trunk key is assigned to the terminal.
In case of using internal and external paging group same time, message will provided when
both paging groups are in idle status. If internal or external paging group is already used,
message will not provided.
In case of speaking status after monitor mode, monitored terminal key does not operate
except speaker key.
When the sensor malfunctions, use Security Sensor Reset Service Code programmed at
Program 11-12-62 to cancel the operation, stop warning message or stop emergency call.
During the Watch mode or Security sensor "On" state, if a system reset occurs these
modes automatically continue after boot up.
When sending a Warning message or placing an emergency call, if system reset occurs
the call state is cleared. Following a boot up, the Warning message or source placing an
emergency call will stop.
If security sensor detects a signal, display below sentence to terminal which set Program
20-08-23 data to 1.