NEC Univerge SV8100 Features And Specifications Manual page 1461

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
80-04-03
Call Progress Tone Detector
Setup – S/N Ratio
80-04-04
Call Progress Tone Detector
Setup – No tone time
80-04-05
Call Progress Tone Detector
Setup – Pulse Count
80-04-06
Call Progress Tone Detector
Setup – ON minimum time
Speed Dial – System/Group/Station
Description/Comments
Define the S/N ratio for the Call
Progress Tone Detector.
Define the no tone time for the Call
Progress Tone Detector.
Define the pulse count for the Call
Progress Tone Detector.
Define the on minimum time for
the Call Progress Tone Detector.
Assigned Data
1
0~4 (0dB ~ -20dB)
default:
Type 1 (DT) – 4
(-20dB)
Type 2 (BT) – 4
(-20dB)
Type 3 (RBT) – 4
(-20dB)
Type 4, Type 5 – 0
0~255
(30+30-7680 ms)
The formula is 30+30N.
When set to N=1, it
means 30+30*1=60
When set to N=255, it
means
30+30*255=7680
(0 =not detect)
default:
Type 1 (DT) – 132
(3990 ms)
Type 2 (BT) – 132
(3990 ms)
Type 3 (RBT) – 132
(3990 ms)
Type 4, Type 5 – 0
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
1~255 (30+30-
7680ms)
default:
Type 1 (DT) – 9
(300ms)
Type 2 (BT) – 12
(300ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
Issue 12.0
Level
2
3
2 - 1431

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents