Program
Program Name
Number
14-02-01
Analog Trunk Data Setup –
Signaling Type (DP/DTMF)
14-02-02
Analog Trunk Data Setup – Ring
Detect Type
14-04-01
Behind PBX Setup
14-05-01
Trunk Group – Trunk Group
Number
20-06-01
Class of Service for Extensions
T1 Trunking (with ANI/DNIS Compatibility)
Description/Comments
For ANI/DNIS, the following
additional settings in Program
14-02 are recommended:
Item 1: Signaling Type (DP/
DTMF) = 2 (DTMF)
Item 2: Ring Detect Type = 1
(Immediate)
Item 3: Flash Type = 0 (Open
Loop Flash)
Item 4: Flash for Time Flash or
Disconnect = 0 (Timed Flash)
Item 5: Dial Tone Detection for
Manually Dialed Calls = 1
(Outgoing calls allowed)
Set the trunks for Extended Ring
Detect or Immediate Ring Detect.
For T1 loop/ground start trunks,
set this option to 1 for the trunks
to ring and light correctly.
For ANI/DNIS, Stand Alone
(Trunk) setting is recommended:
Behind PBX.
For ANI/DNIS, place all your ANI/
DNIS trunks in Trunk Groups as
required.
Assign a Class of Service (1~15)
to an extension.
Assigned Data
1
0=Dial Pulse (10 PPS)
1=Dial Pulse (20 PPS)
2=DTMF
(default = 2)
Trunks 1~200
0 = Normal/delayed
1 = Immediate Ringing
(default = 1)
0 = Stand Alone
(Trunk)
1 = Behind PBX (PBX)
2 = Not Used
3 = CTX Assume 9
(default = 0)
Trunks 1~200
Trunk Port 1~200,
Group 1,
Priority 1~200
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default: Extensions
101 = Class 15
All other extensions =
Class 1
Issue 12.0
Level
2
3
2 - 1567

Hide quick links: