Each site must have a PZ-(X)IPLA/IPLB daughter board and a PZ-ME50-US Memory Expansion
Daughter Board installed on its CD-CP00-US blade. The CD-CP00-US blade at each Remote Site must
have the same data as the Main Site CD-CP00-US blade. The Main Site automatically uploads the
system data to the Remote Sites anytime it changes.
The Main Site requires a proper LK-SYS-NETLINKX-LIC license for each Remote Site.
When a communication failure occurs between the Main Site and any Remote Site, the Main Site
CD-CP00-US blade automatically changes to survival mode and operates as a stand-alone system. If
multiple Remote Sites are installed, a Remote Site can be assigned as a temporary Main Site to control
remaining connected sites.
Conditions
With Version 4000 or higher software, systems using NetLink no longer refer to programs
10-46-06 SIP Registrar Port and 10-46-13 Subscribe Session Port. New programs
51-17-01 and 51-17-02 are used to change the ports on a per system basis when
connecting IP phones via NAPT.
The Primary System (Main Site) requires the appropriate NetLink licenses dependant upon
the number of nodes in the NetLink network.
Up to 16 Nodes can be supported in a NetLink network.
A maximum of 240 Virtual slots are supported.
Port assignment is performed sequentially by the requested order from the Secondary
Systems.
All nodes in a NetLink network should have the same main CD-CP00-US software.
When a Terminal is placed on hold, the Music on Hold comes from the system where the
Terminal resides.
When a trunk is placed on hold, the Music on Hold comes from the system where the trunk
resides.
External Paging uses an output on the CD-CP00-US of the Primary System.
A PGD(2)-U10 ADP must be used if External Paging is required in the Secondary Systems.
License information in the Primary will be copied to the Secondary site when doing
database duplication.
Duplicate license information in the Secondary System is available for only seven days
Version 4000 (4.00 or lower) software.
Duplicate license information in the Secondary System is available for only 28 days.
Version 4000 (4.01 or higher) software required.