Issue 12.0
Program
Program Name
Number
80-03-05
DTMF Tone Receiver Setup –
Forward twist level
80-03-06
DTMF Tone Receiver Setup –
Backward twist level
80-03-07
DTMF Tone Receiver Setup – ON
detect time
80-03-08
DTMF Tone Receiver Setup –
OFF detect time
80-04-01
Call Progress Tone Detector
Setup – Detection Level
80-04-02
Call Progress Tone Detector
Setup – Min. Detection Level
2 - 1430
Description/Comments
Define the forward twist levels for
the DTMF Tone Receiver.
Define the backward twist levels
for the DTMF Tone Receiver.
Define the on detect times for the
DTMF Tone Receiver.
Define the off detect timer for the
DTMF Tone Receiver.
Define the detection levels for the
Call Progress Tone Detector.
Define the minimum detection
levels for the Call Progress Tone
Detector.
UNIVERGE SV8100
Assigned Data
0~9 (1dB~10dB)
[default: Type 1~5 =
5 (6dBm)]
0~9 (1dB~10dB)
[default: Type 1~5 =
0 (1dBm)]
1~255 (15+ 15ms~
3825ms)
[default: Type 1~5 =
1 (30ms)]
1~255 (15+ 15ms~
3825ms)
[default: Type 1~5 =
1 (30ms)]
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
0~15
detect level 0 : –15dBm
(0) to –30dBm(15)
detect level 1 : –30dBm
(0) to –45dBm(15)
detect level 2 : –40dBm
(0) to –55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
Speed Dial – System/Group/Station
Level
1
2
3

Hide quick links: