NEC Univerge SV8100 Features And Specifications Manual page 1617

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
20-11-11
Class of Service Options (Hold/
Transfer Service) – Automatic
On-Hook Transfer
20-11-14
Class of Service Options (Hold/
Transfer Service) –
Trunk-to-Trunk Transfer
Restriction
20-11-21
Class of Service Options (Hold/
Transfer Service) – Restriction
for Tandem Trunking on Hang
Up
24-02-07
System Options for Transfer –
Trunk-to-Trunk Transfer Release
Warning Tone
24-02-10
System Options for Transfer –
Disconnect Trunk-to-Trunk
25-07-07
System Timers for VRS/DISA –
Long Conversation Warning
Tone Time
25-07-08
System Timers for VRS/DISA –
Long Conversation Disconnect
Time
Tandem Trunking (Unsupervised Conference)
Description/Comments
Turn Off or On the Trunk-to-Trunk
Transfer Restriction. If enabled,
Trunk-to-Trunk Transfer is not
possible.
Turn Off or On the Trunk-to-Trunk
Transfer Restriction. If enabled,
Trunk-to-Trunk Transfer is not
possible.
Allow/Deny an extension user
ability to set up a tandem call
automatically when they hang up.
This timer starts when a trunk
begins talking with another trunk
(for example: Trunk-to-Trunk
Transfer, outgoing from trunk,
Tandem Trunking).
When this time expires, a warning
tone is heard. If Program 24-02-10
is set, the conversation
disconnects after time expires.
This time is set again when the
external digit time expires. One of
the trunks used must be an analog
trunk (or leased line).
This timer starts after the
Trunk-to-Trunk warning tone is
heard.
Determine the time a DISA caller
or any trunk-to-trunk (such as
Tandem Trunking) conversation
can talk before the Long
Conversation tone is heard.
Determine the time the system
waits before disconnecting a DISA
or any trunk-to-trunk (such as
Tandem Trunking) conversation
call after the Long Conversation
tone is heard.
Assigned Data
1
0 = Off
1 = On
(default = 0 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~15)
0 = Allow
1 = Deny
(default = 0 for
COS 1~15)
0~64800 (seconds)
(default = 1800)
0~64800 (seconds)
(default = 0)
0~64800 (seconds)
(default = 3600)
0~64800 (seconds)
(default = 10)
Issue 12.0
Level
2
3
2 - 1587

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents