UNIVERGE SV8100
Program
Program Name
Number
80-04-02
Call Progress Tone Detector
Setup – Min. Detection Level
80-04-03
Call Progress Tone Detector
Setup – S/N Ratio
80-04-04
Call Progress Tone Detector
Setup – No Tone Time
UM8000 Mail
Description/Comments
Define the various levels and
timers for the Call Progress Tone
Detector.
Use this option to set the minimum
detection level.
Define the various levels and
timers for the Call Progress Tone
Detector.
Define the various levels and
timers for the Call Progress Tone
Detector.
Use this option to set No Tone
Time.
Assigned Data
1
0~15
detect level 0:
–15dBm(0) to
–30dBm(15)
detect level 1:
–30dBm(0) to
–45dBm(15)
detect level 2:
–40dBm(0) to
–55dBm(15)
default:
Type 1 (DT) = 15
(-25dBm)
Type 2 (BT) = 15
(-25dBm)
Type 3 (RBT) = 15
(-25dBm)
Type 4, Type 5 = 0
0~4 (0dB ~ -20dB)
default:
Type 1 (DT) = 4
(-20dB)
Type 2 (BT) = 4
(-20dB)
Type 3 (RBT) = 4
(-20dB)
Type 4, Type 5 = 0
0~255
(30+30-7680ms)
The formula is 30+30N.
When set to N=1, it
means 30+30*1=60
When set to N=255, it
means
30+30*255=7680
(0 =not detect)
default:
Type 1 (DT) = 132
(3990ms)
Type 2 (BT) = 132
(3990ms)
Type 3 (RBT) = 132
(3990ms)
Type 4, Type 5 = 0